Winland ea200 2 zone enviroalert monitoring device. User manuals, guides and specifications for your winland enviroalert ea200 security system. The supervised under carpet water sensor can be connected to the enviroalert products as well as the wb800. Which is why the enviroalert 2 zone environmental monitor base unit is an investme.
The wb200 accepts up to 6 probes wired per console. The actual ea200 enviroalert digital environmental alarm is a dual zone device. If temperatures andor humidity deviate from the preset limits or water forms a bridge between the contacts on the waterbug sensor, the designate relay for each zone will activate an alarm, dialer, siren, etc. Winland electronics enviroalert ea800 base unit intruder. When a condition deviates from the predetermined threshold both visual and audible notifications occur.
Whether it is a residential or commercial application, enviroalert provides the flexibility to simultaneously monitor temperature, humidity, andor water in one or more critical environments sensor probes sold separately. Buy winland electronics ea20012 enviroalert one to two zone monitoring console allows one remote sensor and more from our comprehensive selection of winland 1 to 2 zone digital environmental monitoring. You do not need to press them down at the same time. Winland electronics temperature alarm, 58 to 299 deg. Youll receive instant notification of arising issues and enjoy peace of mind, knowing your valuable assets are safe from destruction. Winland electronics ea400 user manual 56 pages also. Enviroalert ea40012 four zone digital environmental monitor. User guide read online or download pdf winland electronics ea400 user manual winland electronics measuring instruments. The winland ea200 enviroalert is great for those who want to be notified of. You will need to unlock the unit by pressing alarm silence and enter both down, and then releasing them at the exact same time.
Sensor temperatura y humedad free download as pdf file. From simple manual devices to more advanced digital controllers with sensor feedback, we offer a wide variety of temperature controllers and alarms. Winland enviroalert ea200 manuals manuals and user guides for winland enviroalert ea200. View and download winland electronics enviroalert ea200 quick start manual online. Has memory for user recorded messages to playback when it calls. Enviroalert ea20012 two zone digital environmental monitor. The winland enviroalert ea400 is an environmental monitoring device capable of monitoring any combination of temperature, humidity, and water detection on its four inputs. The enviroalert ea200 criticalenvironment monitoring device provides visibility to 2 environmental factors. Enviroalert ea200 security system pdf manual download.
Enviroalert 2 zone environmental monitor base unit. Enviroalert ea200 temperature controller pdf manual download. Winland ea20012 environmental monitoring alarm tremtech. Unlocking the ea200 you will need to unlock the unit by pressing alarm silence and enter both down, and then releasing them at the exact same time. Winland enviroalert ea200 manuals and user guides, security. Winland electronics ea400 user manual 56 pages also for. Temperature process controllers and alarms from coleparmer india. Poor temperature control can result in lost energy, an inconsistent product, and even equipment and safety concerns. If you choose the 24vdc version, you will receive an ea200 24. Buy enviroalert ea40012 four zone digital environmental monitor alarm, 12 volt dc at a great price. Figure 1 enviroalert ea800 console and optional wireless sensor. Ea20012, wi ea20012 monitor two zones with one onboard temperature sensor and an additional remote temperature, humidity or water sensing probe.
It was used to sense the chilled water temperature via a remote sensor. Winland enviroalert solutions simultaneously monitor temperature, humidity, andor water presence in critical environments. The ea200 12 is compatible with four different temperature probes, a humidity probe and two different water probes. The winland enviroalert ea200 is a two zone environmental monitoring device with one internal ambient temperature sensor, and one input for remote temperature, humidity, or water presence sensor. Database contains 1 winland enviroalert ea200 manuals available for free online viewing or downloading in pdf. Temperature process controllers and alarms can help improve efficiency in your process by properly controlling the temperature. Winland ea200 enviroalert dual zone digital environmental. Temperature process controllers and alarms from coleparmer china. If temperatures andor humidity deviate from the preset limits or water forms a bridge between.
The winland ea200 enviroalert is great for those who want to be notified of climate changes in at home or a business. Buy enviroalert ea20012 two zone digital environmental monitor alarm, 12 volt dc at a great price. Enviroalert ea20012 two zone digital environmental monitor alarm, 12 volt dc. The enviroalert ea200 and ea400 provide alarm signals when monitored conditions exceed the userprogrammable high limit or low limit set points. Get indepth information on winland electronics enviroalert ea800 base unit intruder detectors including detailed technical specifications. Winland ea20012 dual zone digital environmental monitoring alarm, 12v upc. Winland electronics ea20012 enviroalert one to two zone. Temperature process controllers and alarms from coleparmer. The enviroalert ea400 criticalenvironment monitoring device provides visibility of up to 4 environmental factors including temperature, humidity and water detection. Winland ea40012 environmental monitoring alarm tremtech. We have 1 winland enviroalert ea200 manual available for free pdf download. Besides, view the entire catalog of winland electronics enviroalert ea800 base unit intruder detectors winland electronics enviroalert ea800 base unit intruder detectors with specifications of other products from our extensive catalog from leading. Take this time at home and knock out some home improvement tasks.
With a designated relay output for each zone, enviroalert will activate alarms, dialers, transmitters, etc. Order winland electronics temperature alarm, 58 to 299 deg. Winland ea200 2 zone enviroalert monitoring device diy controls. Annually, more property damage and loss is caused by environmental conditions such as water leakage, temperature extremes, humidity and power failure than by theft or fire. You can use this in conjunction with an alarm system or hook it into a voice dialer to call out when the temperature changes in the environment its in. The ea200 24 is compatible with all of the same probes except for the humidity probe. Enviroalert ea20012 zone 1 is an internal room air temperature sensor zone 2 is defective and is not used. Designed for customization, they work for any company or job site. Ea40012 4zone environmental monitoring alarm 12v dc. Ea20012 2zone environmental monitoring alarm 12v dc. The alarm will be activated if water is present as well as if the cable is cut. Scribd is the worlds largest social reading and publishing site. Supervised under carpet water sensor for the waterbug 800, enviroalert 200, enviroalert 400, and enviroalert ea800ip.